Revised Section April 2021 Site Sanitary Sewerage Gravity Service Laterals 3331 16-2 D. Subject to above limits, provide 6-inch service connection when more than one service discharges into single pipe.
Accurately locate in field all proposed service laterals along new sanitary sewer main. Accurately locate in field existing service connections and proposed service laterals along alignment of new parallel or replacement sewer main. Conform to requirements of Section 01 33 00 - Submittals.
What is a Lateral Pipe? - MMSD
Your sanitary sewer lateral is the pipe that carries your wastewater from your home (toilets, sinks, showers, laundry, floor drains, etc.) to the public sanitary sewer main that is typically in the street.
Connecting a Sewer Service Line - Citizens Energy Group
The contractor will dig the trench, install the proposed sanitary sewer lateral pipe, make any necessary connections and leave the trench open. If the contractor is having difficulty locating the lateral stub on the sewer main, they can submit a Lateral Locate Request.
sewer lateral stub Definition - Law Insider
sewer lateral stub means that portion of a sewer lateral from the sanitary sewer to the limit of a Municipal Right of Way.
May 10, 2011 · 2.1.1 New Sewer Service Lateral Connection to an Existing Lateral Stub (3 EDUs or Less) 1. This type of project involves the connection of a new building sewer, or sewer service lateral, to an existing lateral stub. 2. To qualify for this type of project, all construction work shall occur on private property. 3.
Feb 16, 2016 · A service stub is typically a 6‐inch diameter pipe that connects the public sewer system and the privately‐owned and maintained sewer service lateral. The privately‐owned sewer service lateral is an individual customer service line which transports wastewater from one or more buildings to
Sewer stub - Cline Home Remodeling and Repair
In construction, a “sewer stub” refers to a short length of pipe that extends from a building’s plumbing system to the property line, where it connects to the public sewer lateral or septic tank. The sewer stub carries wastewater from the building to the main sewer lateral or septic tank.
SANITARY SEWER LATERALS SHALL BE 4" SDR 26 UNLESS DIRECTED OTHERWISE BY THE OWNER. DOUBLE SWEEP TEES SHALL HAVE SOLVENT WELD JOINTS FOR THE BRANCH CONNECTION AND GASKETED PUSH-ON JOINTS FOR THE RUN CONNECTIONS. NON-SEIZE GREASE SUITABLE FOR USE WITH PVC FITTINGS SHALL BE APPLIED TO THE THREADS OF THE CLEANOUT CAP.
These Standards are applicable for all Laterals which will be connected to HSE’s sanitary sewer system. This includes Projects (including on-site disposal systems) which will not
- Some results have been removed