
Definitions and Concepts: Run-Time, Compile-Time, Tunable, …
Jun 8, 2017 · Some of the Simscape blocks allows to change compile-time to run-time. To see if is allowed, fist go into Matlab Preferences > Simscape > Show run-time parameters settings and check it. Than, open the Simulink, and see if the Simscape blocks constains the option Run-Time and Compile-Time.
Manage Simscape Run-Time Parameters - MathWorks
Manage Simscape Run-Time Parameters. By default, all Simscape™ parameters are compile-time configurable. You can only change the value of compile-time parameters in the plant model on your development computer. Specify Simscape Run-Time Parameters. Some Simscape block parameters are strictly compile-time configurable parameters.
Improve Parameter-Sweeping Efficiency Using Simscape Run-Time …
With Simulink fast restart, you can modify Simscape run-time parameters from the workspace variable, without recompiling. For an example that shows how to specify a Simscape run-time parameter and change the parameter value using fast restart, see Specify and Change a Simscape Run-Time Parameter.
Simulink model rebuilds every time when no changes are made
Apr 30, 2014 · I'm trying to run my model in Rapid Accelerator mode without having it recompile since it takes roughly 45 minutes to compile every time. Have I overlooked some configuration parameter of the model? Is there some global MATLAB/Simulink variable I need to change?
How Simscape Run-Time Parameters and Simulink Tunable
Simscape run-time parameters are run-time configurable. You can only change the value of a run-time configurable parameter when a simulation is stopped. Simulink tunable parameters are tunable by default. Simscape block parameters are only compile-time configurable by default.
Force compiled Matlab app to use runtime rather than a Matlab …
Jun 24, 2018 · The problem is that when the compiled executable runs, there doesn't seem to be an obvious way to force it to use Matlab Compiler Runtime (MCR). If there are Matlab licenses on the target system, it can use that as well.
About Simscape Run-Time Parameters - MathWorks
To specify a Simscape block parameter as run-time configurable, change the Configurability setting, which appears in the block property inspector underneath the parameter name, from Compile-time to Run-time.
Run Code Faster With the New MATLAB Execution Engine
Feb 12, 2016 · With R2015b the execution time between Test1 and Test2 is nearly the same, demonstrating the ability of the new execution engine to JIT compile all MATLAB code. The result is that Test2 executes nearly 90 times faster with the new execution engine in R2015b.
Measure the Performance of Your Code - MathWorks
The timeit function and the stopwatch timer functions, tic and toc, enable you to time how long your code takes to run. Use the timeit function for a rigorous measurement of function execution time. Use tic and toc to estimate time for smaller portions of code that are not complete functions.
Definitions and Concepts: Run-Time, Compile-Time, Tunable, …
Some of the Simscape blocks allows to change compile-time to run-time. To see if is allowed, fist go into Matlab Preferences > Simscape > Show run-time parameters settings and check it. Than, open the Simulink, and see if the Simscape blocks constains the …
- Some results have been removed